In-House Generation Oxygen Ensures Continuous Availability Oxygen, Removing The Risk Of A Production Breakdown Due To Delivery Issues Or Supplier Shortages. It Avoids The Hassle Of Constant Order Processing For Refills And Delivery Costs Associated With Bottled Gases.
Gamma On-Site Oxygen Generators Provide Oxygen For Medical And Commercial Applications In Pakistan.
Generating Your Own Oxygen (O2) On-Site Ensures That Your Business Will Have An Oxygen Supply That Remains Consistent, Dependable, And Is Able To Be Generated To Your Specified Purity Level (Vs. Overpaying For Over Specified Oxygen). Other Benefits Include The Ability To Stop Relying On Third-Party Suppliers For Delivery; Stopping The Cycle Of Locking Your Business Into Contracts With The Gas Suppliers; And Decreasing Your Environmental Footprint By Eliminating Oxygen Transport And Delivery.
How It Works: The Air We Breathe Is About 21% Oxygen. Oxygen For Industrial Use Is Generated By Separating Oxygen Molecules From The Other Molecules Within A Clean, Dry Compressed Air Stream Via Pressure Swing Adsorption (PSA), Which Is A Simple, Reliable And Cost-Effective Technology That Enables Continuous, High-Capacity Oxygen Flow At The Desired Level Of Purity (90% To 95%).
Adsorption Happens When Atoms, Ions, Or Molecules From A Substance (Compressed Air In This Case) Adhere To A Surface Of An Adsorbent. PSA Technology Isolates Oxygen Molecules From Other Molecules (Nitrogen, CO2, Water Vapor And Trace Gases) To Leave High-Purity Oxygen At The Outlet Of The Generator. The Process Takes Place In Two Separate Pressure Vessels (Tower A And Tower B), Each Of Which Are Filled With A Carbon Molecular Sieve, That Switch Between A Separation Process And A Regeneration Process.
Compared To The Delivery Of Gas Bottles Or Tanks Of Oxygen, In-House Generation Of Oxygen Offers Many Key Advantages. For Example, It Ensures Continuous Availability Of Oxygen, Removing The Risk Of A Production Breakdown Due To Delivery Issues Or Supplier Shortages. It Avoids The Hassle Of Constant Order Processing For Refills And Delivery Costs Associated With Bottled Oxygen. It Also Eliminates The Space And Special Handling Requirements For Full Oxygen Bottles In Inventory And Empty Bottles Awaiting Pickup, Refill And Re-Delivery.
Pressure: 1-300 Bar
PSA Oxygen Generators
VPSA Oxygen Generators
Air Separation Unit-O2
⦁ Flow : 1-5000Nm3/Hr
⦁ Purity : 90-99.9%
⦁ Pressure : 1-300 Bar
Compared with VSA technologies, main problem of traditional PSA oxygen generators is the high power consumption. Now with Gamma Gas PSA oxygen generators, the power consumption is remarkably reduced, making PSA oxygen generation more economical.
With Gamma Gas airflow distribution and control system, snow-storm filling technology, and world-top brand parts from Burkert, Bray, Siemens, Weidmuller, etc, Gamma Gas GOM PSA oxygen generators is able to run for more than 10 years without trouble.
This series oxygen generators are skid mounted, easy for transportation and site installation. With a simple touch on screen, within 30 minutes, oxygen with 93% plus purity can be sent to using point.
Gamma Gas PSA oxygen generators, the right choice for onsite oxygen gas generation.
The advanced technology of Gamma Gas GOL low pressure PSA oxygen generator is lower adsorption pressure. With this technology, air compressor working pressure can be as low as 5.0 bar, product oxygen pressure 3-4 bar, it is ideal for fish farming,etc aquaculture industries.
With lower working pressure, this series oxygen generator reduced air compressor power consumption, achieve higher operational reliability.
Gamma Gas GOL low pressure PSA oxygen generator consumes lower compressed air than
Traditional PSA oxygen generator. With Gamma Gas technologies, this oxygen generator can achieve as low as 10:1 air to oxygen ratio. This further reduces operation cost, realizing remarkable energy-saving performance.
Piping Material Features Comparison |
|||
Piping Features | Stainless Steel(Type 304L) | Mild Steel | Blue anodized Aluminum Alloy |
Weight (Dia 6inch, Length 6m) | 127.2 | 169.6 | 29.142 |
Corrosion Resistant | Yes | No | Yes(100%) |
Pressure drop (Dia 2 inch Length= 20m,Airflow=3 cubic metres/Minute, Pressure=10 bar) | 0.25 | 0.4 Bar | 0.1 |
Energy Efficiency | High | Low-moderate | High( Potential Cost savings of 34%) |
Mechanical Strength | Very Strong | Very Strong | Strong |
High-Temperature Rating | Yes | Yes | Yes |
Installation Ease | Less Difficult | Difficult | Easy(High Flexibility and Modularity) |
Installation Time | Approx 6 feet length per hour | Approx 6 feet length per hour | Approx 45 feet Length per hour |
Work Hours/Manpower Required for a 2″ pipe and a 3000 feet piping | Approx 600 man-hours/8 men for 2 weeks | Approx 600 man-hours/8 men for 2 weeks | Approx 100 man-hours /8 men for less than 2 days |
Annual Cost(Installation, Commissioning, and operation) | Approx 3000 dollars | Approx 7820 dollars | Approx 1300 dollars |
Installation Cost Material%/Labor% | 30% / 70% | 25% / 75% | 80% / 20% |
Surface roughness | 0.03 | 0.05 | 0.001 |
Special Tools Required (welder, threader, groove cutter) | Yes | Yes | No |
Air Quality | High(Should the application require it, these pipe systems can help meet the requirements of ISO 8573-1: 2010 air quality standards. | Low( Not according to !SO 8573-2010 air quality standards) | High(Should the application require it, these pipe systems can help meet the requirements of ISO 8573-1: 2010 air quality standards. |
Cost per meter | Almost 2 less than Aluminum | 3 Times less than Aluminum | 163.64 Dollars(Parker Transair) |
Life Span( Will vary according to environmental factors, Pipe design, and Pipe grade. | 30 years | 40 years | 20 years |
Initial Cost of installations | Material : 30% Labor:70% | Material : 25% Labor:75% | Material : 80% Labor:20% |
Maintenance | Difficult(Accumulation of rust under pipes and fittings which travels to machinery, may require preventive maintenance every week) | Difficult (Accumulation of rust under pipes and fittings which travels to machinery may require preventive maintenance every 3-4 days) | Easy (No accumulation of rust, may require preventive maintenance every 4 Weeks) |