AirHorse Screw Air Compressors are engineered to deliver reliable, high-quality compressed air, ensuring uninterrupted operations even in the most demanding industrial environments.
Built with a durable construction, AirHorse compressors are designed to operate continuously, providing consistent air supply for various industrial applications.
These compressors are capable of functioning in ambient temperatures up to 55°C, making them suitable for hot climates and harsh working conditions.
AirHorse compressors are designed for straightforward installation and user-friendly operation, minimizing downtime and simplifying maintenance procedures.
Equipped with advanced noise-reduction technologies, AirHorse compressors operate quietly, ensuring a comfortable working environment.
Incorporating energy-saving features, these compressors help reduce operational costs while maintaining optimal performance.
AirHorse compressors are suitable for a wide range of industries, including manufacturing, automotive, and construction, providing reliable compressed air solutions for various applications.
Model | AHD-10A | AHD-20A | AHD-30A | AHD-40A | AHD-50A | AHD-60A | AHD-75A | AHD-100A | AHD-120A | AHD-150A | AHD-175A | AHD-220A | AHD-250A | AHD-300A | AHD-350A |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Free air deliver / Discharge pressure (m3/min / MPa) | 1.2/0.7 | 1.1/0.8 | 0.9/1.0 | 2.5/0.7 | 2.3/0.8 | 2.1/1.0 | 1.9/1.2 | 3.8/0.7 | 3.6/0.8 | 3.2/1.0 | 2.8/1.2 | 5.2/0.7 | 5.0/0.8 | 4.5/1.0 | 3.8/1.2 |
Free air deliver / Discharge pressure (CFM / PSI) | 42/102 | 39/116 | 32/145 | 88/102 | 81/116 | 74/145 | 67/174 | 134/102 | 127/116 | 113/145 | 99/174 | 184/102 | 177/116 | 159/145 | 134/174 |
Compression stage | Single stage | ||||||||||||||
Ambient temperature | -5~+45℃ | ||||||||||||||
Cooling mode | Air cooling | ||||||||||||||
Discharge temperature | Ambient temperature +15℃ | ||||||||||||||
Lubricant (L) | 3.3 | 10 | 14.5 | 15 | 20 | 45 | 75 | 85 | 120 | 210 | 220 | – | – | – | – |
Noise Level (Db) | 62±2 | 64±2 | 68±2 | 72±2 | 75±2 | 76±2 | – | – | – | – | – | – | – | – | – |
Drive method | Direct driven | ||||||||||||||
Electricity (V/ph/Hz) | 380/3/50 | ||||||||||||||
Motor power (KW / HP) | 7.5/10 | 15/20 | 22/30 | 30/40 | 37/50 | 45/60 | 55/75 | 75/100 | 90/120 | 110/150 | 132/175 | 160/220 | 185/250 | 220/300 | 250/350 |
Starting method | Direct driven / Y-Δ Starter (Star delta starting) | ||||||||||||||
Dimension (mm) | 890*650*810 | 1160*700*1100 | 1200*900*1150 | 1400*900*1225 | 1560*1000*1365 | 1800*1160*1490 | 2100*1400*1780 | 2500*1450*1800 | 2700*1550*1800 | 2800*1550*1950 | 3250*2100*2300 | – | – | – | – |
Net Weight (KG) | 200 | 230 | 415 | 460 | 630 | 705 | 870 | 900 | 1900 | 2150 | 2750 | 3150 | 3450 | 3850 | 4250 |
Air outlet diameter (inch/mm) | 1/2” 3/4” 1” 1 1/2” 2” 2 1/2” DN80 |
Piping Material Features Comparison |
|||
Piping Features | Stainless Steel(Type 304L) | Mild Steel | Blue anodized Aluminum Alloy |
Weight (Dia 6inch, Length 6m) | 127.2 | 169.6 | 29.142 |
Anti-Corrosive | Yes | No | Yes(100%) |
Pressure drop (Dia 2 inch Length= 20m, Airflow=3 cubic metres/Minute, Pressure=10 bar) | 0.25 | 0.4 Bar | 0.1 |
Efficient Energy Use | High | Low-moderate | High( Potential Cost savings of 34%) |
Structural Durability | Very Strong | Very Strong | Strong |
High Thermal Endurance | Yes | Yes | Yes |
Installation Ease | Less Difficult | Difficult | Easy(High Flexibility and Modularity) |
Simple Installation | Approx 6 feet length per hour | Approx 6 feet length per hour | Approx 45 feet Length per hour |
Manpower and Work Hours Needed for 2″ Pipe Over 3000 Feet | Approx 600 man-hours/8 men for 2 weeks | Approx 600 man-hours/8 men for 2 weeks | About 100 man-hours with 8 workers, completed in under 2 days |
Annual Charges for Installation, Commissioning & Operation | Approx 3000 dollars | Approx 7820 dollars | Approx 1300 dollars |
Installation Cost Breakdown: Material % / Labor % | 30% / 70% | 25% / 75% | 80% / 20% |
Texture of Surface | 0.03 | 0.05 | 0.001 |
Required Specialized Tools: Welder, Threader, Groove Cutter | Yes | Yes | No |
Quality of Air | High — When needed, these pipe systems comply with ISO 8573-1:2010 air quality standards | Low( Not according to !SO 8573-2010 air quality standards) | High — These pipe systems support compliance with ISO 8573-1:2010 air quality standards when required. |
Cost Rate per Meter | Almost 2 less than Aluminum | 3 Times less than Aluminum | 163.64 Dollars |
Service Life Depends on Environment, Pipe Design, and Grade | 30 years | 40 years | 20 years |
Upfront Installation Cost | Material : 30% Labor:70% | Material : 25% Labor:75% | Material : 80% Labor:20% |
Care and Maintenance | Difficult — Rust buildup under pipes and fittings can reach machinery, requiring weekly preventive maintenance. | Difficult (Accumulation of rust under pipes and fittings which travels to machinery may require preventive maintenance every 3-4 days) | Easy — No rust buildup, with preventive maintenance needed every 4 weeks. |